AC Motor

HF-YZ Series allows for quick and easy tube changes, providing high precision and rigidity. It can be fitted with 3 and 6 rollers. The material of the rollers is 304/316 stainless steel which resists corrosion. Two types of housing material for the option, PPS and PSF.

Characteristic



Industry application

Support COD on-line monitor

Anorectal therapeutic instrument

Tubing Installation Procedure

    1. Lift upper block.
    Lift lever according to sign direction to 180º degrees in the opposite direction. 

    2.  Install tube.
    Lift cartridge the install tube.

    3.  Upper block reset.
    Lift lever according to sign direction to original position.

    4.  Enter work state.
    Push upper block to original position and tighten the tube. Then enter work state.

Application


Pump Head and Flow Rate

Pump Head Tubing IDxWall thickness (mm) ml/r Flow Rate (ml/min) 0.1-600rpm Tubing Max. Pressure (Mpa) Intermittent Tubing Max. Pressure (Mpa) Continuous Material/Weight (kg) PSF Material/Weight (kg) PPS
HF-YZ1515x 13# 0.8×1.6 0.07 0.007~42 0.27 0.17 0.40 (3 rollers) 0.46 (3 rollers)
HF-YZ1515x 14# 1.6×1.6 0.27 0.027~162 0.27 0.17 0.40 (3 rollers) 0.46 (3 rollers)
HF-YZ1515x 19# 2.4×1.6 0.55 0.055~330 0.27 0.17 0.40 (3 rollers) 0.46 (3 rollers)
HF-YZ1515x 16# 3.1×1.6 0.82 0.082~492 0.27 0.17 0.40 (3 rollers) 0.46 (3 rollers)
HF-YZ1515x 25# 4.8×1.6 1.7 0.17~1020 0.24 0.14 0.40 (3 rollers) 0.46 (3 rollers)
HF-YZ1515x 17# 6.4×1.6 2.9 0.29~1740 0.14 0.10 0.44 (6 rollers) 0.50 (6 rollers)
HF-YZ1515x 18# 7.9×1.6 3.8 0.38~2280 0.10 0.07 0.44 (6 rollers) 0.50 (6 rollers)
HF-YZ2515x 15# 4.8×2.4 1.7 0.17~1020 0.27 0.17 0.44 (6 rollers) 0.50 (6 rollers)
HF-YZ2515x 24# 6.4×2.4 2.9 0.29~1740 0.27 0.17 0.44 (6 rollers) 0.50 (6 rollers)

Motor Specification

Model No. OEM-J06
Motor type AC motor
Voltage AC110V/220V
Power consumption 10W
Motor size φ60mm
Speed (rpm) 417
Speed error ≤±10%
Dimension (LxWxH) 229x94x129mm
Working temperature 0-40ºC
Relative humidity <80%

Product Dimension Drawing (mm)