42 Integrated closed-loop stepper motor 2

Exquisite appearance, small size. The upper pressing block is opened by a turning method, and the operation is simple. The elastic upper block can reduce tubing wear. Quickly replace tubing with self-adaptive tube clamp. Suitable for 5 different sizes of hoses to meet different flow requirements.

Characteristic



Industry application

Biotechnology and pharmaceutical

Chemical and food industries

Tubing Installation Procedure

    1. Lift the flip top of the pump head to open the pump head.

    2.  Adjust the tube holder to the position corresponding to the installed size.

    3.  Put the tubing into the pump head.

    4.  Close the flip top of the pump head downward to complete the installation.

Pump Head and Flow Rate

Pump Head Channel number Tubing IDxWall Thickness (mm) ml/r (0.1-600rpm) Flow rate (ml/min) Weight (kg)
HF-KT15 Single Channel 13# 0.8×1.6 0.033 0.0033~19.97 0.096
HF-KT15 Single Channel 14# 1.6×1.6 0.156 0.0156~93.42 0.096
HF-KT15 Single Channel 19# 2.4×1.6 0.286 0.0286~171.6 0.096
HF-KT15 Single Channel 16# 3.1×1.6 0.477 0.0477~286.32 0.096
HF-KT15 Single Channel 25# 4.8×1.6 0.933 0.0933~560.04 0.096

Technical Specification

Model No. OEM-KTB023
Speed range 0.1-600rpm
Flow rate range 0.0033-560.04ml/min
Control mode RS485 communication
Motor type 42 Integrated closed-loop stepper motor
Communication address 1-32 (Factory default is 1)
Signal output Open-Collector output
Communication protocol Support MODBUS protocol (RTU mode)
Power supply DC24V-36V, ≥36W
Working environment 0-40ºC, 80%RH

Product Dimension Drawing (mm)